Heating-Up Chamber CALDERA
FAST AND EFFECTIVE HEATING OF SAMPLES
A Caldera is a device for fluid warming
Functionality:
- capacities: 70, 150, 200, 250, 300l - dimensions and load examples are specified in the table with technical data
- fast heating-up of the load due to forced air convection
- polished stainless steel housing, stainless steel interior
- bright, energy saving LED internal lighting and tempered glass of the door assure an excellent visibility of the interior
- drawers with telescopic slides instead of regular shelves prevent falling out of the load
- possibility to place Caldera on the stainless steel table - option
CALDERA are designed to heat samples as quickly as possible. Most often the load is liquids, which have an optimum temperature for use in the range of 35-42°C. CALDERA heating chambers, in order to best fulfil their function as a chamber for heating liquids, are equipped as standard with drawers with raised rims on telescopic slides.
Heating-Up Chamber CALDERA 70
- temperature range +35…+42°C (+35...+70°C in the TERM version)
- chamber capacity 68 liters
- working capacity 68 liters
Heating-Up Chamber CALDERA 150
- temperature range +35…+42°C (+35...+70°C in the TERM version)
- chamber capacity 150 liters
- working capacity 150 liters
Heating-Up Chamber CALDERA 200
- temperature range +35…+42°C (+35...+70°C in the TERM version)
- chamber capacity 200 liters
- working capacity 200 liters
Heating-Up Chamber CALDERA 250
- temperature range +35…+42°C (+35...+70°C in the TERM version)
- chamber capacity 250 liters
- working capacity 250 liters
Heating-Up Chamber CALDERA 300
- temperature range +35…+42°C (+35...+70°C in the TERM version)
- chamber capacity 300 liters
- working capacity 300 liters
KKP Climatic Chambers
EASY TO USE…, EASY TO MAINTAIN… EASY TO BE ECO
The innovative Peltier technology in the Climatic Chambers KKP
Peltier technology in KKP series provides stable, silent, vibration free climatic conditions, keeping superior temperature variation and fluctuation, and it’s space-saving. The tests performed at a temperature close to the ambient temperature shows the impressive economy of the heating and cooling concept with Peltier thanks to which KKP doesn’t require any refrigerant and is therefore nearly maintenance-free. Due to the fact that the efficiency of Peltier appliances in certain conditions is much better than of climate chambers with refrigerant dependent cooling systems, the KKP 240 makes a significant contribution to improving the climate balance.
Applications
- Stability tests according to ICH Q1A
- Breeding of certain insects, mice
- Plant cultivation
Climatic Chamber KKP 240
- temperature range without humidity 0…+70°C (max 20°C below ambient temp.)
- temperature range with humidity +5…+70°C (max 20°C below ambient temp.)
- chamber capacity 245 liters
- working capacity 245 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber KKP 750
- temperature range without humidity 0…+70°C (max 20°C below ambient temp.)
- temperature range with humidity +5…+70°C (max 20°C below ambient temp.)
- chamber capacity 749 liters
- working capacity 749 liters
- quality control protocol (at +25°C, 60%rH)
Humidification with a steam generator
The KKP constant climatic chambers with a steam humidifier do not emit ultrasounds and therefore allow insects breeding (e.g. Drosophila melanogaster). Compared to the KK chambers, they feature an extended temperature and humidity range and can be used for tests of electronics, plastic or building materials.
Steam humidifier in the KKP models is an energy-saving solution based on an aluminum heating block and a peristaltic pump controlled by a stepper motor. This humidifier has a very fast heating time and enables the dosing of precisely measured amounts of water. Operation in ECO mode (the block heats up only when it detects the need for dosing moisture to the chamber) saves energy.
How does a Peltier cooling-heating system work?
Climatic Chambers
THE RIGHT CLIMATE FOR YOUR RESEARCH
The climatic chambers of POL-EKO are devices in which temperature and humidity are parameters that can be almost freely simulated
-These are specialized chambers for testing under constant environmental conditions. The most important feature is the ability to create stable conditions through precise temperature and humidity control.
- Aging test chambers, allow to maintain stable temperature parameters (0. . 60°C for KK series or 0. . 100°C for KKS series) and humidity (30. . 90% for KK series and ultrasonic humidifier or 10. . 90% for KKS series steam humidifier).
Climate chambers are specialized test chambers for aging tests, stability tests, thermal or climatic tests.
POL-EKO devices are equipped with a modern touch screen Smart PRO controller. The chamber is made of high quality acid resistant steel. The unit has double door with lock.
Climatic Chambers with an Ultrasonic Humidifier
Climatic chambers with ultrasonic humidifier are professional and reliable equipment to guarantee stable and precise conditions. The max temperature of 60°C allows use of them for seed germination, fungus and plant growing or food tests. Perfect climatic conditions allow stability tests of pharmaceuticals and cosmetics, as well as packaging and electronics
Climatic Chamber KK 115
- temperature range 0…+60°C
- chamber capacity 109 liters
- working capacity 109 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber KK 240
- temperature range 0…+60°C
- chamber capacity 240 liters
- working capacity 240 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber KK 350
- temperature range 0…+60°C
- chamber capacity 322 liters
- working capacity 283 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber KK 400
- temperature range 0…+60°C
- chamber capacity 416 liters
- working capacity 416 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber KK 500
- temperature range 0…+60°C
- chamber capacity 470 liters
- working capacity 392 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber KK 700
- temperature range 0…+60°C
- chamber capacity 600 liters
- working capacity 485 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber KK 750
- temperature range 0…+60°C
- chamber capacity 749 liters
- working capacity 749 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber KK 1200
- temperature range 0…+60°C
- chamber capacity 1330 liters
- working capacity 1132 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber KK 1450
- temperature range 0…+60°C
- chamber capacity 1485 liters
- working capacity 1264 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chambers with an Steam Humidifier
The KKS climatic chambers with steam humidifier do not emit ultrasounds and therefore allow insects breeding (e.g. Drosophila melanogaster). Compared to the KK chambers, they feature an extended temperature and humidity range and can be used for tests of electronics, plastic or building materials.
Climatic Chamber KKS 115
- temperature range 0…+100°C
- chamber capacity 109 liters
- working capacity 109 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber KKS 240
- temperature range 0…+100°C
- chamber capacity 240 liters
- working capacity 240 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber KKS 400
- temperature range 0…+100°C
- chamber capacity 416 liters
- working capacity 416 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber KKS 750
- temperature range 0…+100°C
- chamber capacity 749 liters
- working capacity 749 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chambers With Phytotron System
SIMULATION OF DAY AND NIGHT, ALSO POSSIBLE WITH UV LAMPS
Climatic chambers with phytotron are the only group of units that allows controlling of humidity, temperature and lighting altogether
- programming of temperature, humidity and lighting
- day and night simulation system with smooth regulation of light intensity:
- fluorescent tubes placed in door and side walls
- fluorescent tubes placed in side walls
- fluorescent tubes placed in door
- mounted as a panel with overhead lighting
- Temperature range when the light is off (night): 0. . . +60°C
- Temperature range with lighting off (daytime): +10. . . +50°C
- choice of light colour
- maximum light intensity - 15 000 LUX per shelf (measurement performed in the geometrical center of the shelf placed 25 cm below the lighting panel)
Climatic Chambers with Phytotron and Overshelf Lighting Panels
Climatic Chamber With Phytotron System KK 115 FIT P
- temperature range 0…+60°C with lighting +10...+50°C
- chamber capacity 109 liters
- working capacity 96 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber With Phytotron System KK 240 FIT P
- temperature range 0…+60°C with lighting +10...+50°C
- chamber capacity 240 liters
- working capacity 222 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber With Phytotron System KK 400 FIT P
- temperature range 0…+60°C with lighting +10...+50°C
- chamber capacity 416 liters
- working capacity 390 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber With Phytotron System KK 500 FIT P
- temperature range 0…+60°C with lighting +10...+50°C
- chamber capacity 470 liters
- working capacity 365 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber With Phytotron System KK 700 FIT P
- temperature range 0…+60°C with lighting +10...+50°C
- chamber capacity 600 liters
- working capacity 423 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber With Phytotron System KK 750 FIT P
- temperature range 0…+60°C with lighting +10...+50°C
- chamber capacity 749 liters
- working capacity 749 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber With Phytotron System KK 1200 FIT P
- temperature range 0…+60°C with lighting +10...+50°C
- chamber capacity 1330 liters
- working capacity 1132 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber With Phytotron System KK 1450 FIT P
- temperature range 0…+60°C with lighting +10...+50°C
- chamber capacity 1485 liters
- working capacity 1264 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chambers with Phytotron and Lighting In Door
Phytotron chambers with in-door lighting are available in 3 sizes:115, 240 and 750. Climatic Chambers With Phytotron System can be suitable to individual customer requirements. A wide range of additional equipment and the possibility of implementing non-standard solutions makes these devices satisfy even the most demanding users.
Climatic Chamber With Phytotron System KK 115 FIT D
- temperature range 0…+60°C with lighting +10...+50°C
- chamber capacity 109 liters
- working capacity 109 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber With Phytotron System KK 240 FIT D
- temperature range 0…+60°C with lighting +10...+50°C
- chamber capacity 240 liters
- working capacity 222 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber With Phytotron System KK 750 FIT D
- temperature range 0…+60°C with lighting +10...+50°C
- chamber capacity 749 liters
- working capacity 749 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chambers with Phytotron and Lighting In Side Walls
Climatic Chamber With Phytotron System KK 500 FIT S
- temperature range 0…+60°C with lighting +10...+50°C
- chamber capacity 470 liters
- working capacity 386 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber With Phytotron System KK 700 FIT S
- temperature range 0…+60°C with lighting +10...+50°C
- chamber capacity 600 liters
- working capacity 450 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chambers with Phytotron and Lighting In Door and Side Walls
The most even illumination of the entire chamber, is possible when using lighting from three sides. Phytotron chambers with lighting installed in doors and walls offer such an opportunity. The light source may be fluorescent lamps with individually selected parameters such as temperature and color of light or LED panels, also with individually selected parameters.
Climatic Chamber With Phytotron System KK 350 FIT DS
- temperature range 0…+60°C with lighting +10...+50°C
- chamber capacity 322 liters
- working capacity 283 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber With Phytotron System KK 500 FIT DS
- temperature range 0…+60°C with lighting +10...+50°C
- chamber capacity 470 liters
- working capacity 386 liters
- quality control protocol (at +25°C, 60%rH)
Climatic Chamber With Phytotron System KK 700 FIT DS
- temperature range 0…+60°C with lighting +10...+50°C
- chamber capacity 625 liters
- working capacity 450 liters
- quality control protocol (at +25°C, 60%rH)