Home » Knick » Knick ORP Sensors

Knick ORP Sensors

Knick logo-small

Knick’s ORP sensors are available in different versions – analog or digital with Memosens technology – even with explosion protection.

Thanks to the different sensor lengths and multiple connection options, they can be adapted to different fittings. These fittings include retractable fittings such as SensoGate and Ceramat, inline fittings, flow-through fittings, and immersion fittings to satisfy a broad range of application requirements.

orp-sensors-xx-knick-pa-products

MemoSuite Sensor Management Tool

Memosens contactless sensor coupling

SE555 pH/ORP Sensor | Memosens | 120 mm-image

SE555 pH/ORP Sensor | Memosens | 120 mm

  • Product Details
  • Additional Information

Ex | CIP/SIP capable | Sterilizable | For aggressive media

Steam-sterilizable sensor providing high reliability and precision, digital, with Memosens technology

  • Simultaneous measurement of pH and ORP
  • Gel electrolyte, pressurized and long-term stable
  • Ceramic junction
  • Silver ion trap
  • Integrated temperature detector
  • Omega glass with high impedance for high-temperature applications, very low alkali error
  • CIP/SIP capable, safe sterilization with temperature monitoring
  • Perfect galvanic isolation thanks to Memosens technology
  • No influence of humidity in the connector
  • Precalibration in the lab
  • Digital data transfer
  • Integrated sensor diagnostics

The digital pH/ORP sensor SE555X/1-AMSN has a special pH glass with high impedance for high-temperature applications and low alkali error as well as a platinum disk as ORP measuring element.

The sensor is CIP and SIP capable. The silver ion trap prevents contamination and blocking of the junction by silver sulfide in sulfide-containing media. The reference electrolyte is biocompatible. This makes the sensor predestined for applications in food and biotechnology, but it is also suitable for continuous and simultaneous measurement of pH and ORP in process chemistry or wastewater.

In addition, the Memosens technology offers all known advantages in terms of handling and sensor diagnostics.

Applications
Fermentation, food and beverages, aggressive media, extreme pH values, waste water

Specifications


Measurement Parameter:pH, ORP 
Connector:Memosens
Measuring Range:0 … 14 pH, ± 1500 mV
Explosion protection:Yes
Length:120 mm
Process Connection:PG 13.5
Temperature Detector:NTC 30 kΩ
Junction:Ceramic (1×)
Reference System:Ag/AgCl with silver ion trap. Gel electrolyte, pressurized
Electrolyte:Gel electrolyte with pressure pads
Relative process pressure:-1 … 6 bar (-14.5 … 87 psi)
Wetted materials:Body → Glass, Electrode (ORP) → Platinum, Junction → Ceramic, Sensor tip → Omega glass
Process Temperature:0 … 135 °C (32 … 275 °F)
Tightening torque:1 ... 3 Nm
Electrical connection:Memosens connector

Categories: Measurement Parameter,Length,Connector,Explosion protection
Sub-Categories: pH/ORP,120 mm,Yes,Memosens