Knick’s conductivity sensors offer all measuring principles: 2-electrode, 4-electrode, and inductive. The analog and digital conductivity sensors cover a wide range of measurement requirements, from ultra-pure water to highly concentrated acids and alkaline solutions, and they are available with explosion protection.

The sensors are compatible with inline, flow-through, and immersion fittings, guaranteeing versatility in a variety of installation configurations and applications.

conductivity-sensors-xx-knick-pa-products

MemoSuite Sensor Management Tool

Memosens contactless sensor coupling

SE605H 2-Electrode Conductivity Sensor | Memosens-image

SE605H 2-Electrode Conductivity Sensor | Memosens

  • Product Details
  • Additional Information

Ingold socket | Hygienic design

Robust 2-electrode sensor, for precise and reliable measurement of low and very low conductivities, particularly in ultrapure water, digital, with Memosens technology

  • Perfect galvanic isolation thanks to Memosens technology
  • Digital data transfer
  • Integrated sensor diagnostics
  • Large measuring range from ultrapure water to 1000 μS/cm
  • Hygienic design
  • Electropolished – Roughness Ra ≤ 0.4 or ≤ 0.8 μm
  • FDA-certified materials
  • Coaxially arranged electrodes
  • Independent of installation conditions
  • Integrated temperature detector
  • High level of process safety due to durable materials and robust design
  • Easy to clean thanks to replaceable outer and inner electrode
  • Particularly suitable for monitoring ultrapure water in power plants
  • Replaceable gaskets

Robust sensor with hygienic design made of stainless steel in coaxial arrangement. Large measuring range from ultrapure water to 1000 μS/cm. Integrated temperature detector for temperature compensation. Easy to clean thanks to replaceable outer and inner electrode.

Applications
Ultrapure water, WFI (water for injection), pharmaceutical and food industry, biotechnology

Specifications


Measurement Parameter:Conductivity
Connector:Memosens
Measuring Range:0 … 1,000 µS/cm
Explosion protection:No
Process Connection:Ingold socket
Temperature Detector:NTC 30 kΩ
Pressure:Max. 10 bar (135 °C), Max. 25 bar (–20 … 70 °C)
Wetted materials:Stainless steel 1.4435; isolator PEEK; seals: see product line
Cell constant:0.021/cm

Categories: Measurement Parameter,Connector,Explosion protection
Sub-Categories: CONDUCTIVITY,No,Memosens