pH Measurement

ph electrodes type

600P

pH Range0 ~ 14 pH
Temperature Range0 ~ 80 °C
Reference TypeSingle junction
FeatureDurable PC housing
Cable Length1 m
ConnectorBNC
ApplicationGeneral measurement

600C

pH Range2 ~ 12 pH
Temperature Range0 ~ 60 °C
Reference TypeSingle junction
FeatureGlass electrode
Cable Length1 m
ConnectorBNC
ApplicationPure water and tap water

600S-pH

pH Range0 ~ 14 pH
Temperature Range0 ~ 80 °C
Reference TypeDouble junction
FeatureEpoxy housing. planar electrode
Cable Length1 m
ConnectorBNC or other
ApplicationGeneral measurement

6810P / 6003P / 6005P

pH Range0 ~ 14 pH
Temperature Range0 ~ 80 °C
Reference TypeSingle Junction
FeatureTemperature Compensation
Cable Length1m
ConnectorATC+BNC
ApplicationGeneral measurement

pH Measurement

ph electrodes type

GB6005 / GB6003

pH Range0 ~ 14 pH
Temperature Range0 ~ 80 °C
Reference TypeSingle junction
Feature3 in 1 Glass electrode (10K Temperature Compensation) KCL addible
Cable Length1 m
ConnectorBNC+DIN / BNC+ATC
ApplicationGeneral measurement

GB700E

pH Range0 ~ 14 pH
Temperature Range0 ~ 80 °C
Reference TypeSingle junction
FeatureGlass electrode, KCL addible
Cable Length1 m
ConnectorBNC
ApplicationGeneral measurement

GB711E

pH Range0 ~ 14 pH
Temperature Range0 ~ 80 °C
Reference TypeDouble junction
FeatureGlass electrode, KCL addible
Cable Length1 m
ConnectorBNC
ApplicationResistance to strong acid and alkali

GB712E

pH Range0 ~ 14 pH
Temperature Range0 ~ 80 °C
Reference TypeDouble junction
FeatureGlass electrode, LiCl addible
Cable Length1m
ConnectorBNC
ApplicationMeasure the organic sample

pH Measurement

ph electrodes type

GB713E

pH Range0 ~ 14 pH
Temperature Range0 ~ 80 °C
Reference TypeSingle junction
FeatureDurable PC housing
Cable Length1 m
ConnectorBNC
ApplicationPuncturable meat, vegetables or fruits

GB715E

pH Range0 ~ 13 pH
Temperature Range0 ~ 80 °C
Reference TypeSingle junction
FeaturePlanar composite electrode
Cable Length1 m
ConnectorBNC
ApplicationSuitable for micro sample, e.g. skin, paper, cloth, dough

GB716E

pH Range0 ~ 14 pH
Temperature Range0 ~ 80 °C
Reference TypeDouble junction
FeatureGlass electrode, KCL addible
Cable Length1 m
ConnectorBNC
ApplicationComposite electrode for test tube

GB707E

pH Range0 ~ 14 pH
Temperature Range0 ~ 100 °C
Reference TypeSingle Junction
FeatureGlass electrode
Cable Length1 m
ConnectorBNC
ApplicationStrong acid, alkali, partial organic solution or viscous oil

pH Measurement

ph electrodes type
GB710T electrode

GB710T

pH Range0 ~ 14 pH
Temperature Range5 ~ 60 °C
Reference TypeDouble junction
FeatureCusp glass electrode
Cable Length1 m
ConnectorBNC
ApplicationSuitable for heavy metals, protein, TRIS

GB710E electrode

GB710E

pH Range0 ~ 14 pH
Temperature Range5 ~ 90 °C
Reference TypeDouble junction
FeatureGlass electrode, KCL addible
Cable Length1 m
ConnectorBNC or other
ApplicationStrong acid, alkali, partial organic solution or viscous oil

2511-Z electrode

2511-Z

pH Range0 ~ 14 pH
Temperature Range5 ~ 60 °C
Reference TypeSingle junction
FeatureGlass electrode
Cable Length1 m
ConnectorBNC (2511-Z-B) or Y type connector (2511-Z-Y)
ApplicationGeneral measurement

618P electrode

618P

pH Range0 ~ 14 pH
Temperature Range0 ~ 60 °C
Reference TypeSingle junction
Feature3 in 1 electrode (include temperature)
ConnectorSpecial for PH618N /
PH630 / pH619
ApplicationGeneral measurement

pH Measurement

ph electrodes type
80P electrode

80P

pH Range0 ~ 14 pH
Conductivity Range0 ~1999 uS/cm
Temperature Range-5 ~ 60 °C
FeatureSingle junction
Cable Length5 in 1 electrode
ConnectorSpecial for pH/EC80
ApplicationGeneral measurement

IP-600-1N

IP-600-1N

pH Range0 ~ 14 pH
Temperature Range-5 ~ 110 °C
Reference TypeDouble junction
Pressure Tolerance0 ~ 500 psig (at 25 °C)
FeatureGlass electrode
Cable Length20 m
ConnectorBNC or Y type connector
Application High pressure, viscous material. Normal temperature fermentation

IP-600-9 PT TH

IP-600-9 PT/TH

pH Range0 ~ 14 pH
Temperature Range0 ~ 80 °C
Reference TypeDouble junction
Pressure Tolerance0 ~ 500 psig (at 25 °C)
FeatureDurable PPS housing and glass sensor
Cable Length5 m or other
ConnectorBNC or other
ApplicationWastewater, sewage treatment

IP-600-15N PT TH

IP-600-15N PT/TH

pH Range0 ~ 14 pH
Temperature Range0 ~ 60 °C
Reference TypeSingle junction
Pressure Tolerance0 ~ 100 psig (at 25 °C)
FeatureDurable PPS housing and glass sensor
Cable Length5 m or other
ConnectorBNC or other
ApplicationWastewater, sewage treatment

pH Measurement

ph electrodes type
IP-600-10

IP-600-10

pH Range0 ~ 14 pH
Temperature Range0 ~ 80 °C
Reference TypeDouble junction
Pressure Tolerance0 ~ 100 psig (at 25 °C)
FeatureDurable PPS housing and glass sensor
Cable Length20 m or other
ConnectorBNC or other
ApplicationWastewater, sewage treatment

IP-600-10

IP-600-3CN PT/TH

pH Range2 ~ 12 pH
Temperature Range0 ~ 60 °C
Reference TypeSingle junction
Pressure Tolerance0 ~ 100 psig (at 25 °C)
Temp. CompensationPt100 (IP-600-3CPT), TH10K (IP-600-3CTH)
FeatureDurable PPS housing and glass sensor
Cable Length5 m or other
ConnectorBNC or other
ApplicationPure water treatment

IP-600-3C

IP-600-3C

pH Range2 ~ 12 pH
Temperature Range0 ~ 60 °C
Reference TypeSingle junction
Pressure Tolerance0 ~ 100 psig (at 25 °C)
FeatureDurable PPS housing and glass sensor
Cable Length20 m or other
ConnectorBNC or other
ApplicationPure water treatment

ORP Measurement

ORP measurement icon
600S-ORP

600S-ORP

ORP Range-2000 ~ 2000 mV
Temperature Range0 ~ 80 °C
Reference TypeSingle junction
FeatureEpoxy housing. planar electrode (platinum sensor)
Cable Length1 m or other
ConnectorBNC or other
ApplicationApplied to redox testing

600L-ORP

600L-ORP

ORP Range±1999 mV
Temperature Range0 ~ 80 °C
Reference TypeSingle junction
FeatureGlass electrode (platinum band sensor)
Cable Length1 m or other
ConnectorBNC or other
ApplicationApplied to redox testing

IR-500-9N

IR-500-9N

ORP Range-1000 ~ 1000 mV
Temperature Range0 ~ 80 °C
Reference TypeSingle junction
Pressure Tolerance0 ~ 100 psig (at 25 °C)
FeatureDurable PPS housing and platinum band sensor
Cable Length20 m or other
ConnectorBNC or other
ApplicationSwimming pool, wastewater, sewage treatment

IR-500-8

IR-500-8

ORP Range-2000 ~ 2000 mV
Temperature Range0 ~ 80 °C
Reference TypeDouble junction
Pressure Tolerance0 ~ 100 psig (at 25 °C)
FeatureDurable PPS housing and platinum band sensor
Cable Length5m or other
ConnectorBNC or other

Conductivity Measurement (EC)

EC electrodes type
101C

101C

Conductivity Range50.0 uS/cm to 200.0 mS/cm
Temperature Range0 ~ 80 °C
Cell ConstantK=0.475
Feature4-wire electrode. Graphite sensor
Cable Length1 m
Connector8 pin
ApplicationHigh-precision routine testing and measurement of high- concentration dielectric conductivity

106A-L

106A/L

Conductivity Range0 ~ 30 mS/cm
Temperature Range5 ~ 90 °C
Cell ConstantK=1.0
Feature2-wire electrode, platinum sensor
Cable Length1 m
Connector4 pin / 8 pin
ApplicationGeneral liquid measurement

107A-N

107A/N

Conductivity Range0 ~ 200 mS/cm
Temperature Range0 ~ 80 °C
Cell ConstantK=1.0
FeatureEpoxy housing, platinum sensor
Cable Length3 m
Connector4 pin / 8 pin
ApplicationHigh conductivity liquid measurement

109A-L-P

109A/L/P

Conductivity Range0 ~ 200 uS/cm
Temperature Range0 ~ 80 °C
Cell ConstantK=1.0
FeatureGlass Housing, platinum sensor
Cable Length1 m
Connector4 pin / 8 pin
ApplicationLow conductivity liquid measurement

Conductivity Measurement (EC)

EC electrodes type
3020P 3840P

3020P / 3840P

Conductivity Range50.0 uS/cm ~ 200.0 mS/cm
Temperature Range0 ~ 80 °C
Cell ConstantK=0.475
Feature4-wire electrode. Graphite sensor
Cable Length1 m
Connector6 pin
ApplicationGeneral water treatment

330P

330P

Conductivity Range0.00 ~ 20.00 mS/cm
Temperature Range0 ~ 60 °C
Feature2-wire electrode, temperature compensation
ConnectorSpecial for EC330
ApplicationGeneral water measurement

331P

331P

Conductivity Range0 ~ 200 uS/cm
Temperature Range0 ~ 60 °C
Feature2-wire electrode, temperature compensation
ConnectorSpecial for EC331
ApplicationPure water measurement

392-126_A

392-126

Conductivity Range0 ~ 200 uS/cm
Temperature Range0 ~ 100 °C
Cell ConstantK=0.1
Pressure Tolerance100 psig (at 25 °C)
Feature2-wire electrode, temperature compensation
Cable Length5 m or other
Connector3/4” NPT
ApplicationPure water treatment

Conductivity Measurement (EC)

EC electrodes type
392-125

392-125

Conductivity Range0 ~ 10 mS/cm
Temperature Range0 ~ 100 °C
Cell ConstantK=1
Pressure Tolerance100 psig (at 25 °C)
FeatureIndustrial EC probe, 10K thermistor
Cable Length5 m or other
Connector3/4” NPT
ApplicationGeneral water treatment

392-122

392-122

Conductivity Range0 ~ 20uS/cm
Temperature Range0 ~ 100 °C
Cell ConstantK=0.01
Pressure Tolerance100 psig (at 25 °C)
FeatureIndustrial EC probe, 10K thermistor
Cable Length5 m or other
Connector3/4” NPT
ApplicationPure water treatment

EC621-01

EC621-01 / EC621-001

Conductivity Range0.5 ~ 200 uS/cm (EC621-01) 0.05 ~ 20 uS/cm (EC621-001)
Temperature Range0 ~ 140 °C
Cell ConstantK=0.1 K=0.01
Pressure Tolerance0 ~ 150 psig (at 135 °C)
Feature2-wire electrode
Cable Length5 m
Connector3/4” NPT
ApplicationBoiler, pure water treatment

EC621-1

EC621-1 /
EC621-10

Conductivity Range0.01 ~ 2 0 mS/cm
1 ~ 200 mS/cm
Temperature Range0 ~ 80 °C
Cell ConstantK=1 K=10
Pressure Tolerance0 ~ 70 psig (at 25 °C)
Feature2-wire electrode
Cable Length5 m
Connector3/4” NPT
ApplicationBoiler, pure water treatment

Conductivity Measurement (EC)

EC electrodes type
EC621-05

EC621-05

Conductivity Range50 uS/cm ~ 200 mS/cm
Temperature Range0 ~ 80 °C
Cell ConstantK=0.475
Pressure Tolerance0 ~ 100 psig (25 °C)
Feature4-wire electrode
Cable Length5 m
Connector3/4” NPT
ApplicationSurface water, sewage and seawater

25-Series

25-Series

Conductivity Range0 ~ 200 uS/cm (25-0.1)0.01 ~ 20 mS/cm (25-1.0) 0.1 ~ 200 mScm (25-10)
Temperature Range0 ~ 80 °C
Cell ConstantK=1 K=10
Feature2-wire electrode
Cable Length10 m
Connector3/4” NPT
ApplicationRecycling water and high concentration water

Dissolved Oxygen (DO)

DO measurement icon
LD-900-7

LD-900-7

DO Range0 ~ 20.00 mg/L (ppm) or 0 ~ 200%
Response Time30 secs to attain 95% of actual reading
FeatureEPOXY housing. Gold and Ag sensor
Cable Length1m
Connector8 pin
ApplicationOrdinary water, river or sewage

LD-900-10

LD-900-10 /
LD-900-11

DO Range0~20.00 mg/L (ppm) or 0~200.0%
Response Time30 secs to attain 95% of actual reading (at 25 °C)
FeaturePolarographic. Gold and Ag sensor
Cable Length4 m or other
Connector8 pin / 6 pin
ApplicationOrdinary water, river or sewage

LSDO-4

LSDO-4

DO Range0~20.00 mg/L (ppm) or 0~200.0%
Response Time30 secs to attain 95% of actual reading (at 25 °C)
FeatureLuminescent Dissolved Oxygen electrode. Temperature compensation
Cable Length4 m
Connector4 pin
ApplicationOrdinary water, river or sewage

OXYSENS 120

OXYSENS 120

DO Range0~40 ppm (mg/L)
Response Time60 secs to attain 98% of actual reading
Pressure Tolerance0~4bar
FeaturePolarographic. Stainless housing
Cable Length5 m or other
ConnectorPG 13.5
ApplicationAquaculture, wastewater, sewage

Accessories

007N

007A

DimensionsArm: 455 mm Base: 159mm (Diameter)
MaterialABS and cast-iron
ApplicationHolding up to 5 standard electrodes

007A

007A

DimensionsArm: 455 mm Base: 159mm (Diameter)
MaterialABS and cast-iron
ApplicationHolding up to 5 standard electrodes